Description
701118 – AIR REGULATOR AND LUBRICATOR – Works with all Harshaw, Engelhard, Atotech USA, Atlas and Auto Technology Company fog and cyclic corrosion test chambers. PURPOSE: The purpose of the optional Air Regulator And Lubricator Assembly is to supply properly regulated compressed air to the optional automated air cover lifters. LOCATION: This assembly is located in the right side wall of the control cabinet area. It is found by removing the front access panel on the control cabinet. When removed, the Air Regulator and Lubricator Assembly is visible. It is located on the right side wall of the control cabinet area. FUNCTION: Customer supplied compressed air (clean, dry and regulated to 95psi / 655kPa) enters the assembly. This air further regulated and filtered, and then lubricated. This conditioned air is then supplied to the optional automated air cover lifters. The filter should be replace at least once per year, or more often as needed, and the lubricant reservoir should be monitored monthly to ensure that it is at the proper level.
Additional information
Weight | 2 lbs |
---|---|
Dimensions | 7 × 7 × 7 in |