ASTM G85 A1 Test Solution, 55-Gallon Drum – C173330
$230.00
Pre-mixed acetic acid-salt solution formulated strictly for ASTM G85 Annex A1 continuous salt spray testing. Designed for laboratories requiring standardized, repeatable exposure conditions without the safety hazards and pH balancing challenges of manual in-house batching.
- Volume: 55-Gallon Drum
- Application: Acetic Acid-Salt Spray (ASTM G85 A1)
- Shipping: LTL Freight Only
- Note: Made-to-order item; non-returnable.
- Volume: 55 Gallon Drum
- Application: ASTM G85 Annex A1 (Acetic Acid-Salt Spray)
- Shipping: LTL Freight Only
- Note: Non-returnable / Made-to-order item.
Description
Pre-Mixed Acetic Acid-Salt Solution for ASTM G85 A1 (55 Gallon Drum)
This pre-mixed acetic acid-salt solution provides laboratory managers and testing technicians with a standardized, ready-to-use supply for ASTM G85 Annex A1 continuous salt spray testing.
ASTM G85 A1 requires the addition of glacial acetic acid to a standard 5% sodium chloride solution to achieve a strict pH range (typically 3.1 to 3.3). By eliminating the need for manual, hazardous in-house batching and fine-tuning, this solution helps testing facilities maintain strict pH controls, minimize operator exposure to raw chemicals, and ensure repeatable test conditions. It is delivered in a 55-gallon drum to support high-volume continuous testing.
Operational Benefits for Testing Laboratories
- Standardizes test inputs: Eliminates the variability of manual pH balancing between different operators and shifts.
- Enhances laboratory safety: Removes the need for technicians to handle, measure, and store hazardous glacial acetic acid in the lab.
- Maintains compliance: Formulated specifically to meet the strict chemical and pH requirements of the ASTM G85 Annex A1 standard.
- Optimizes labor: Reduces technician preparation time during test setup.
- Improves repeatability: Provides baseline consistency for evaluating decorative copper/nickel/chromium or nickel/chromium coatings.
Solution Preparation Comparison
| Factor | Manual In-House Mixing | ATC Pre-Mixed Solution |
|---|---|---|
| pH & Concentration Accuracy | Operator dependent | Controlled |
| Hazardous Chemical Exposure | High (Glacial Acetic Acid) | Low |
| Labor Requirement | High (Mixing & pH tuning) | Zero |
| Batch Repeatability | Variable | Consistent |
Applications
- ASTM G85 Annex A1 continuous acetic acid-salt spray testing
- Evaluation of decorative copper/nickel/chromium or nickel/chromium coatings
- Corrosion testing on steel or zinc-based die castings
- General modified salt fog exposure testing
Product Specifications
- Application: ASTM G85 Annex A1
- Solution Type: Pre-mixed acetic acid and sodium chloride solution
- Volume: 55 Gallons
- Part Number: C173330
Compatibility
Suitable for use in standard salt fog and salt spray test chambers equipped to handle the lower pH and modified spray requirements mandated by the ASTM G85 standard.
Freight & Shipping Requirements
This product requires LTL freight shipping due to its volume and weight.
Orders consisting of more than two drums must be palletized. Please add the Skid / Crating Charge (Part C260150) to your cart prior to checkout.
- Each skid holds a maximum of 4 drums.
- Example: 4 drums = 1 skid; 8 drums = 2 skids.
Shipping Options
- Collect: Provide your preferred freight carrier and account number during checkout.
- Prepay & Add: We will arrange the freight shipment and add the cost to your invoice.
Important Ordering Note
To ensure maximum shelf life and batch consistency, this is a made-to-order product. As such, it is non-returnable. Please verify your testing requirements and laboratory capacity prior to ordering.
Questions & Support
For assistance with order quantities, freight arrangements, or testing compatibility, please contact our Sales team at (440) 572-7800.
Frequently Asked Questions
Is this solution ready to use?
Yes. This is a pre-mixed acetic acid-salt solution supplied ready for immediate use in ASTM G85 Annex A1 testing applications.
What tests is this solution used for?
This solution is intended strictly for continuous acetic acid-salt spray testing adhering to the requirements of the ASTM G85 Annex A1 standard.
Do I need to mix or add acetic acid before using it?
No. This product is supplied pre-mixed with the correct ratios of sodium chloride and acetic acid to hit the target pH, eliminating the safety risks and labor of in-house batching.
What size is the container?
This product is supplied in a standard 55-gallon drum.
Does this item ship by parcel or freight?
Due to its size and weight (approx. 500 lbs), this item must ship via LTL freight.
Do orders of 3 or more drums require a skid charge?
Yes. Orders exceeding two drums must be palletized for safe transit. You will need to add the required skid/crating charge to your cart before checking out.
Is this item returnable?
No. To guarantee solution integrity and prevent contamination, this is a made-to-order item and is non-returnable.
Additional information
| Weight | 500 lbs |
|---|---|
| Dimensions | 25 × 25 × 36 in |