GMW 14872 CYCLIC CORROSION TEST CHAMBER – X14872

Thin horizontal red-to-gray gradient bar

The Auto Technology X14872 cyclic corrosion chamber runs complete GMW 14872 cycles. Select the preprogrammed cycle for the specified exposure. The chamber applies direct salt spray, opens to laboratory air during ambient holds, and completes the humid and heated dry-off stages automatically.

Size 20 X14872 with specimen access ports
Size 20 shown with optional specimen access ports.

Adjustable perimeter spray

Use short extensions for nearby surfaces and longer ones to reach around brackets or fixtures. Aim each flexible head at the part in its mounted position. The controller sets when the spray starts and how long it runs.

Watch the X Series deluxe spray demonstration

Chamber loaded with parts between perimeter spray heads
Spray-head positions around a loaded fixture.

Computer-controlled cover lifters for true ambient exposure

In the original manual GM corrosion cycle, operators sprayed the parts and left them in laboratory air during the ambient holds. The X14872 reproduces that exposure with the parts in place. The standard computer-controlled pneumatic cover lifters raise the cover during programmed ambient holds and close it for humidity and heated drying.

Size 110 chamber with cover raised
Size 110 with the cover open for ambient exposure.
GMW 14872 cover lifters in operation

Preprogrammed GMW cycles

Select a GMW 14872 cycle using the chamber’s computer control. Adjust the spray schedule, ambient holds, humid and dry stages, or cycle repeats to match the GM test plan.

X Series computer displaying the chamber software
X Series computer control interface.

GMW 14872 base cycle and special options

A typical GMW 14872 cycle takes approximately 24 hours. The GM drawing or test plan identifies the method, part location and exposure that determine the spray schedule. Examples include four sprays per cycle for exterior or underbody parts, one per cycle for certain splash-protected underhood locations, and one at the start and every five cycles thereafter for specified interior surfaces.

Base cycle stageConditions during the approximately 8-hour stage
Salt application and ambient holdsDuring ambient holds the open chamber exposes the parts to laboratory air at 25 ±3 °C and 45 ±10% RH.
High humidityReach 49 ±2 °C and approximately 100% RH within one hour. The transition counts toward the stage duration.
Heated dry-offReach 60 ±2 °C and no more than 30% RH within three hours. The transition counts toward the stage duration.

GMW 14872 exposure schedules and test procedures

Special exposure options

If the drawing calls out one of the following options, include it in the RFQ so ATC can identify any additional chamber hardware, separate equipment or operator steps.

GM optionWhat to specify
1 · DustComponent, dust application and any freshwater rinse.
3 · Key cylindersHose-applied salt solution, dust and freshwater rinse.
4 · Thermal soakComponent temperature, soak duration, spray sequence and available oven.
5 · Exhaust condensateAdditional condensate application for rear bumpers or exhaust tips.
6 · Galvanic corrosionFour applications per cycle of a 3% sodium chloride and fireclay mixture and a modified eight-hour stage at approximately 66 °C. Specify delivery equipment suitable for the solids.

GM deleted Option 2.

Chamber sizes and drawings

SizeNominal capacity (ft³)Approx. volume (L)Internal L × W × H (in.)Base L × W (in.)
202059450 × 29 × 2595 × 43
303089175 × 29 × 25120 × 43
40391,10675 × 36 × 25120 × 50
90902,55076 × 45 × 45132 × 68
1101123,19489 × 73 × 30137 × 85
View Size 20 drawings
Base length: 95 in.
View Size 40 drawings
Base length: 120 in.
View Size 110 drawings
Base length: 137 in.

X Series chamber sizes and configurations

Electrical service and installation

Standard X Series current ratings at 60 Hz are shown below. Use the factory electrical drawing for the amperage and feeds on the quoted chamber.

Size208 V / 1 ph208 V / 3 ph240 V / 1 ph240 V / 3 ph460 V / 3 ph
2035 A30 A30 A26 A16 A
3044 A40 A38 A34 A20 A
4044 A40 A38 A34 A20 A
9053 A53 A47 A47 A25 A
110See drawingSee drawingSee drawingSee drawingSee drawing

For room conditions and utility connections, see the chamber installation guide.

X Series accessories and test solutions

View chamber accessories and test solutions

GMW X14872 frequently asked questions

Can the chamber run different GMW 14872 exposures?

Yes. Select the preprogrammed GMW cycle for the specified exposure and adjust the settings to match the test plan. Include any special options in your quote request so ATC can confirm the hardware.

How does the chamber expose parts to laboratory air?

Computer-controlled pneumatic cover lifters open the cabinet during programmed ambient holds. Parts stay on the fixture between spray, humidity and dry-off stages.

Can the X14872 run ASTM B117 salt fog?

Yes. The X14872 includes conventional salt fog for ASTM B117. GMW 14872 uses direct salt spray.

Request an X14872 quote

Send the GM drawing or test-plan excerpt with the revision, method, part location, exposure designation and any special option. Include the largest part’s dimensions and weight, its mounting orientation, quantity per run and available electrical service. A fixture drawing or photo helps us check clearance and spray access.